IMIS - Marine Research Groups | Compendium Coast and Sea

IMIS - Marine Research Groups

[ report an error in this record ]basket (0): add | show Print this page

Comparison of Chelex based resins in diffusive gradients in thin-film for high resolution assessment of metals
Zhou, C.; van de Velde, S.; Baeyens, W.; Gao, Y. (2018). Comparison of Chelex based resins in diffusive gradients in thin-film for high resolution assessment of metals. Talanta 186: 397-405. https://dx.doi.org/10.1016/j.talanta.2018.04.085
In: Talanta. Elsevier: Amsterdam. ISSN 0039-9140; e-ISSN 1873-3573, more
Peer reviewed article  

Available in  Authors 

Keyword
    Marine/Coastal
Author keywords
    Diffusive gradients in thin-film (DGT); Chelex-100; SPR-IDA; Capacity;Ground Chelex-100; High resolution

Authors  Top 

Abstract
    The passive sampling technique of diffusive gradients in thin-film (DGT) is widely used to determine 1D profiles (using Chelex-100 resin) and 2D images (using suspended particulate reagent-iminodiacetate resin, abbreviated as SPR-IDA resin) of metals in sediment pore waters and in oxic/anoxic soils. However, when deployed in anoxic sediments with high metal concentrations, Fe and Mn concentrations determined with the Chelex-100 resin gel were similar to 5 times higher than concentrations measured with the SPR-IDA resin gel. This discrepancy suggests that the SPR-IDA resin gel is saturated faster than the Chelex-100 resin gel. Here, we tested the adsorption capacity of the SPR-IDA resin gel and compared it to the Chelex-100 resin gel. Fe and Mn binding capacities on a SPR-IDA gel disc are less than 0.1 mu moles, which means that they are far below those on a Chelex-100 gel disc (around 3.2 mu moles), while competition with stronger binding metals such as Cu and Cd further lowers Fe and Mn capacities. This restricts the SPR-IDA resin gel to be used in contaminated marine sediments. We propose the use of a ground Chelex-100 resin, which is prepared by grinding Chelex-100 resin in a ball-mill prior to gel preparation. The capacities of Fe and Mn on a ground Chelex-100 resin gel disc are around 1.6 mu moles, more than 16 times higher than the capacity on SPR-IDA gel disc. In addition, the bead size of the ground Chelex-100 resin is small enough (similar to 10 mu m) to allow high resolution LA-ICP-MS imaging of Fe, Mn and trace metals in sediment pore waters as well as soils.

All data in the Integrated Marine Information System (IMIS) is subject to the VLIZ privacy policy Top | Authors